Quadstat
4810 Overhead Balanced Ionization
Blower
The
Quadstat 4810 was designed
specifically for fast charge
neutralization . The unit has 4 fans
and uses steady state D.C.
Ionization .The Quadstat 4810 has
been designed to meet Class 100
cleanroom requirements. Each fan has
a sealed plenum chamber around it to
provide minimal contamination and
ensuring that no particles are
introduced into the air stream.
Features:
Machined
Tungsten Emitter Pins, Key Lockout
Switch, Static Guard Sentry alerts
for cleaning while unit is still in
specifications, Easy access to air
filter and emitter points.
Benefits:
Fast, easy
maintenance, Tamper proof, Stable
balance and fast charge
neutralization over entire work
surface, Meets Class 100 Cleanroom
requirements, Ensures safety of
static - sensitive devices, ideal
for ISO - 9000 requirements
Ion
Emissions: Steady State
D.C.
Dimensions: 2.50”
H X 6.00” D X 40” Long Weight:
13 LBS
Input Power:
110/120/220/240 VAC, 50/60HZ, 75
Watts fuse protected
Controls: On/Off
Switch, Variable Fan Speed Control,
Fan Control Key Switch - lock power
on, high speed fan settings.
Indicators: Power
On ( Illuminated Rocker Switch),
Preventative Maintenance System: Red
LED ( optional audible alarm
available)
Emitter Points:
machined tungsten, four per fan, no
replacement necessary, damaged
emitter points are field
replaceable.
Chassis: steel
chassis with epoxy polyester paint
Air Flow: High fan
speed: 240 FPM
Low fan speed: 150
FPM Measurement taken 12” below
with a rotating Vane Anemometer.
Coverage Area: 4’
X 2’ ( 121.9 X 60.96 CM)
Air Filters:
Anodized Aluminum
Audible Noise: High
Fan Speed - 62 db
Low Fan Speed - 59 db Measurement
taken 12” below fan
Mounting: U - brackets and
S - Hooks provided, convenience
outlet allows up to 5 units to be
connected together and operated from
one power source.
Maintenance: Easily
removed access door provides easy
access to fan stack. Visual
inspection or cleaning of emitter
points and balance check recommended
at 3 month intervals in critical
areas. System indicates when emitter
points cleaning is required.
Certifications: UL
Pending , CE Compliant
Performance:
Ion Balance:
Long term stability+/- 5 volts
Adjustable to zero
Discharge Time: 4
seconds under center of unit.
15 seconds average for coverage
area.
Measurement taken at high fan speed.
Testing was performed with a charge
plate monitor in accordance with
Ionization Standard ANSI EOS/ESD
s3.1-1991 of the ESD Association.
|